← Labs 06

Closed-Loop Buck Converter

Power electronics

A synchronous step-down converter with a continuous-time LL–CC state solver and switching-ripple reconstruction. Sweep duty cycle, source voltage, load, inductance, capacitance, and carrier frequency; the laboratory identifies conduction mode, efficiency, ripple, and transient settling in real time.

live circuit · mode=full continuous conduction · 7.50 V out
Closed-Loop Buck Converter12 components and 15 connections.iLVINVingatefbPWMCTRLPWMQHQHSWswitch nodeD1DfreeL1LVOUT_NODEregulated railVOUT_PROBEVoutCOUTCoutRLOADRloadRETURNpower returnGND0 V
Closed-Loop Buck Converter

Drag a value tag to change that part. Click a wire to clip a probe on.

Probes
Operating points

Buck-converter animation running.

causal signal trace paused

Sample demand The controller compares feedback against the regulation target.

step 1 / 5 Sample demand

Notebook · 12 parts · 15 wires · continuous-time averaged state space

recommended lab 6 of 18

Predict averaged buck-converter output and recognize conduction-mode boundaries.

Builds on: Dynamic RC Low-Pass Filter

predict · then test

In continuous conduction, increase DD while VinV_{in} stays fixed. What should vov_o do?

Commit before the explanation appears. This is a prediction, not a quiz score.

governing model
i˙L=DVin−voL,v˙o=iL−vo/RC\dot i_L = \dfrac{D V_{in}-v_o}{L},\quad \dot v_o = \dfrac{i_L-v_o/R}{C}
structural inventory
  • PWM feedback controller
  • PMOS high-side switch
  • Schottky freewheel diode
  • LL–CC output network
boundaries
  • Vin:5V_{in}: 5–36 V36\ \mathrm V
  • fsw:20f_{sw}: 20–500 kHz500\ \mathrm{kHz}
  • CCM / BCM / DCM classification
diagnosis challenge Fault identity withheld: infer it from the changed outputs first.